MEDUMAT Standard A

Assisted ventilation with MEDUMAT Standard a

Under assisted ventilation MEDUMAT Standarda gives the patient a ventilator breath in response to an inspiratory trigger. When the patient‘s respiratory efforts reach the trigger threshold, MEDUMAT Standarda delivers a mechanical breath to the patient. If the patient does not trigger a breath within the window for inspiration, the patient will receive controlled ventilation.

Double stroke process

If the selected maximum ventilation pressure is exceeded, for example, during Cardiopulmonary Resuscitation (CPR), MEDUMAT Standarda will briefly switch to expiration and attempt to administer a ventilator breath in the same inspiratory phase. With this doublestroke procedure, the patient receives the maximum ventilation volume.

Description

MEDUMAT Standarda offers you everything you need for reliable emergency ventilation. Users around the world are impressed by its especially simple operation and ruggedness. With controlled and assisted ventilation we provide you with the ventilation options you require in an emergency. Our diverse modules let you add many supplemental functions, such as CPAP therapy. When there‘s not a second to lose, the well-designed operating panel with special symbols and colors helps you to quickly set the right ventilation parameters. When placed on our portable LIFE-BASE system, MEDUMAT Standarda has practically unlimited mobility.

Ventilate reliably and properly

An advantage MEDUMAT Standarda has over manual ventilation is the option of setting constant values for tidal volume, ventilation frequency and minute volume. These settings help to prevent ventilator-induced injuries. Furthermore, with a ventilator you can reliably prevent hyperventilation and damaging pressure peaks. That reduces the intrathoracic pressure, which in turn improves venous reflow and cardiac output (ERC Guidelines 2010). You can keep your hands free to provide additional care to the patient. If a problem arises, the ventilator emits acoustic and visual alarms.

Top reliability

  • Automatic self-test when ventilator is switched on
  • Color coding and arrow system simplifies fast and safe parameter settings for each patient group
  • Settings for respiratory minute volume, respiratory rate and maximum ventilation pressure are individually adjustable
  • Visual and acoustic alarms warn of acute problems such as stenosis, disconnection, loss of oxygen pressure, inadequate battery capacity, system failure, missing patient trigger

Economical and flexible

  • Air Mix function reduces FiO2 to about 60% and with that the overall oxygen consumption
  • No internal oxygen consumption for operation
  • No external power supply necessary
  • Can be combined with all WEINMANN Emergency modules, such as MODUL CPAP
  • Assist function can be activated as needed